When purchasing power transformers, you should first confirm the project application, rated capacity, primary and secondary rated voltages, frequency, number of phases, impedance, connection group, voltage regulation method, insulation and cooling, losses, temperature rise, installation environment, accessories, test standards, and delivery scope. Configurations vary across projects; selection should not be based solely on capacity or voltage level, but rather on approved single-line diagrams, load data, and technical specifications.

What Projects Use Power Transformers?

Power transformers are used for electrical energy conversion between different voltage levels. Common procurement scenarios include:

  • Substation and power grid expansion projects.
  • Large factories and industrial facilities.
  • Infrastructure such as transportation and public facilities.
  • New energy projects including solar, wind, and energy storage.

These projects have different requirements for capacity, voltage, insulation levels, and accessories. Actual applications and installation conditions should be specified during inquiries.

Oil-Immersed or Dry-Type?

Oil-immersed power transformers use insulating oil for insulation and heat dissipation, and are commonly used in substations, outdoor facilities, and some large industrial projects. When purchasing, confirm the tank structure, cooling method, insulating oil requirements, and protection accessories.

Dry-type power transformers use solid insulation materials and are common in indoor distribution and projects with specific oil management requirements. Attention should be paid to ventilation, temperature rise, protection, and installation space.

Neither type should be judged superior simply by price or capacity; the final choice must comply with the project environment, fire safety conditions, and technical specifications.

How to Choose the Voltage Regulation Method?

Power transformers can adopt off-circuit tap-changing or on-load tap-changing. Off-circuit tap-changing usually requires adjustment under specified conditions with the equipment powered off; on-load tap-changing can be adjusted under specified operating conditions, suitable for projects with corresponding voltage regulation needs. Whether on-load tap-changing is required should be confirmed based on power grid requirements, project specifications, and procurement documents.

What Parameters Are Needed for Inquiries?

Buyers are advised to provide the following at one time:

  • Rated capacity, as well as primary-side and secondary-side rated voltages.
  • Rated frequency, number of phases, short-circuit impedance, and connection group.
  • Tapping range, voltage regulation method, insulation level, and cooling method.
  • No-load loss, load loss, and temperature rise requirements.
  • Indoor or outdoor installation, altitude, ambient temperature, protection, and anti-corrosion requirements.
  • Quantity, destination country, packaging, transportation, and delivery location.

Capacity and voltage levels should be based on approved single-line diagrams, load data, and final technical specifications, rather than determined solely by equipment quantity.

Accessories and Documentation Checklist

Depending on the product type and project requirements, quotations should clearly state whether they include high and low voltage bushings, radiators or cooling equipment, oil level, temperature and pressure protection, on-load tap-changers, monitoring equipment, terminal boxes, and grounding accessories.

Suppliers should also clearly provide technical parameter sheets, outline drawings, wiring diagrams, applicable standards, routine test reports, and project-required type tests, special tests, or factory acceptance test documents.

How to Compare Supplier Quotations?

When comparing quotations, core parameters such as capacity, voltage, impedance, voltage regulation, cooling, insulation, losses, and temperature rise should be standardized, and designated accessories, test scope, technical documents, export packaging, transportation, delivery time, and warranty scope should be checked. If suppliers have different testing or delivery scopes, clarify the differences before comparing prices.

How Easysail Can Help

Easysail Transformer provides power transformer products and export procurement support. You can submit project single-line diagrams, technical specifications, capacity, voltage, and procurement quantities, and we can assist with product matching, communicating supplier parameters, comparing quotations, checking documents, and coordinating inspection and delivery.