How to Select Cast Resin Dry Type Transformers?

Easysail Transformer Published

When purchasing cast resin dry type transformers, you should first confirm the rated capacity, voltage, winding insulation structure, cooling method, and installation environment, and then verify the enclosure, temperature monitoring, fans, losses, partial discharge test data, and scope of supply. When making an inquiry, ask the supplier to write the winding structure, rated capacity under cooling conditions, and accessories item by item into the configuration table to facilitate comparison based on the same scope.

What Structures Should Be Confirmed for Cast Resin Products?

The common practice for cast resin dry type transformers is that the high voltage winding uses resin casting insulation, while the low voltage winding can use other insulation and manufacturing structures.

When purchasing, you should ask the supplier to specify the high and low voltage winding structures, insulation materials, and product model. Different structures may differ in appearance, heat dissipation, and manufacturing process. Please check the specific structure of each winding in combination with the technical parameter table and drawings.

How to Verify Capacity and Electrical Specifications?

The inquiry should list the rated capacity, primary and secondary rated voltages, frequency, number of phases, connection group, short-circuit impedance, tapping range, insulation level, and temperature rise requirements.

Capacity must be confirmed in combination with cooling conditions. If the supplier provides both natural air cooling and fan-assisted cooling rated values, please confirm the rated capacity and applicable conditions separately.

Projects that need to maintain a certain load when the fans are out of service should state the required natural cooling rated capacity in the specification.

How Do Installation Environment and Enclosures Affect Configuration?

The purchaser should state the indoor or outdoor installation location, ambient temperature, altitude, humidity, dust, and ventilation conditions, and confirm whether a protective enclosure is required.

Enclosure materials, protection grades, cable entry and exit locations, and ventilation structures may affect equipment heat dissipation and installation space. The supplier should state the environmental conditions, enclosure, and cooling configuration corresponding to the quoted capacity.

Projects in special environments should provide technical requirements in advance to avoid suppliers quoting only according to conventional indoor conditions.

How to Choose Temperature Controllers, Fans, and Accessories?

Cast resin dry type transformers can be equipped with temperature sensors, temperature controllers, alarm interfaces, cooling fans, and control accessories according to project requirements. The scope of supply for each accessory shall be subject to the quoted configuration table.

When purchasing, you should confirm whether temperature measurement locations, signal interfaces, number of fans, enclosures, terminals, and vibration damping accessories are included, as well as related control requirements.

Suppliers should distinguish between standard body configurations, optional accessories, and individually priced items to avoid the same model quotation corresponding to different scopes of supply.

How to Compare Loss and Partial Discharge Test Data?

When comparing no-load losses, verify the test voltage and frequency. When comparing load losses, verify the rated capacity, tap position, and reference temperature, and ensure that the quotations use the same basis.

Partial discharge (PD) is an important verification item for cast resin insulation products. The test conditions, limit values, report types, and corresponding product models stipulated in the contract should be clearly defined.

Please use the routine test records of this batch of equipment to check the delivered equipment, use the type test data to check the design coverage, and list the applicable standards and test documents to be delivered in the quotation.

Cast Resin Transformer Procurement Checklist

  • Capacity, voltage, frequency, number of phases, and connection group.
  • High and low voltage winding structures, insulation levels, and impedance.
  • Temperature rise, cooling method, and corresponding rated capacity.
  • Altitude, temperature and humidity, ventilation, and enclosure protection requirements.
  • Temperature controllers, sensors, fans, and terminal accessories.
  • Losses, partial discharge, and other agreed test documents.
  • Outline drawings, accessory list, package dimensions, and weight.
  • Delivery time, trade terms, warranty, and scope of delivery.

When comparing quotations, product configurations, test documents, designated accessories, and packaging and transportation conditions should be standardized, and it should be confirmed whether the factory acceptance witness required by the project is included.

How Easysail Can Assist

Easysail Transformer can assist buyers in matching cast resin dry type transformers based on technical specifications, verifying product structures, capacities, accessories, quotations, and test documents, and coordinating inspection, packaging, and export delivery.