When procuring photovoltaic step-up transformers, you should first confirm the inverter-side voltage, grid-connection side voltage, rated capacity, single-unit or multiple-unit configuration, and whether it's oil-immersed or dry-type. Additionally, you need to specify the frequency, phase number, impedance, vector group, tap changing method, harmonic and loss requirements, installation environment, accessories, test documentation, and scope of delivery. The electrical configuration varies across different photovoltaic projects, so the transformer model cannot be determined solely by the total installed PV capacity.
What Projects Use Photovoltaic Step-Up Transformers?
Photovoltaic step-up transformers are primarily used to convert the voltage from the inverter output side to the voltage level required by the project's grid-connection or collection system. Common procurement scenarios include:
- Centralized PV power plants: Procuring step-up transformers based on inverter and collection system configurations.
- Commercial & Industrial (C&I) PV projects: Used for factory rooftops, industrial parks, and other distributed PV systems.
- Large-scale new energy projects: Configuring single or multiple transformers according to the project's grid-connection scheme.
Common step-up requirements may involve voltage levels from the low-voltage side to 10kV, 20kV, or 33kV, among others. These are merely application examples; the actual voltage should be based on project grid-connection requirements and technical documentation.
First, Confirm Inverter Voltage and Grid-Connection Voltage
This is the most crucial foundational information when procuring photovoltaic step-up transformers. Buyers should clarify:
- Rated AC output voltage of the inverter.
- Rated voltage of the transformer's grid-connection side or collection side.
- Rated capacity required by the project.
- Single transformer unit or multiple distributed units.
- Input and output frequency and phase number.
The capacity should be confirmed based on the project's approved single-line diagram, inverter output parameters, and grid-connection requirements, and cannot be simply determined directly by the total power of the PV modules. If the project already has a single-line diagram and technical specifications, these should be prioritized for submission to suppliers to prevent different quotations from using varying capacity and voltage conditions.
What Technical Parameters Are Required for Photovoltaic Step-Up Transformers?
When requesting a quotation, it is advisable to specify the following:
- Rated capacity: kVA or MVA.
- Voltage ratio: Rated voltage of the inverter side and grid-connection side.
- Frequency and phase number: 50Hz or 60Hz, single-phase or three-phase.
- Impedance: To be confirmed according to project grid-connection and technical requirements.
- Vector group: To match system connection requirements.
- Tap changing: Confirm the adjustment method and range.
- Insulation level: To be determined according to system voltage and applicable standards.
- Losses and temperature rise: Specify no-load loss, load loss, and temperature rise requirements.
- Harmonic conditions: Provide inverter-related harmonic data and project requirements.
The output characteristics of photovoltaic inverters may affect the operating conditions of the transformer, therefore, inquiries should not be based solely on the conventional parameters of standard distribution transformers.
Oil-Immersed or Dry-Type? How to Confirm the Installation Environment?
Photovoltaic projects can choose between oil-immersed or dry-type step-up transformers based on design requirements. Oil-immersed products are commonly used for outdoor step-up applications and power facilities; dry-type products can be used indoors or in specific project environments that meet installation conditions. When procuring, you should also clarify:
- Indoor or outdoor installation.
- Natural or forced cooling method.
- Ambient temperature and installation altitude.
- Anti-corrosion, protection, and dust-proof requirements.
- Noise limitations and heat dissipation conditions.
- Equipment dimensions and transportation restrictions.
The specific product type should be determined based on project technical specifications, installation environment, and local requirements.
What Accessories Need to Be Confirmed in the Quotation?
Standard configurations may vary between different products, so it is advisable to check each item:
- High and low voltage bushings and connection accessories.
- Radiators or cooling fans.
- Oil level indicator and temperature monitoring devices.
- Pressure protection devices.
- Terminal box and control accessories.
- Monitoring interfaces and project-specified components.
These accessories are not fixed configurations for all products; they should be based on the actual product structure and project requirements, and it should be confirmed whether they are included in the quotation.
How to Verify Supplier Technical Documents and Quotations?
When procuring photovoltaic step-up transformers, it is recommended to focus on confirming:
- Product technical data sheet and outline drawing.
- Primary system-related interfaces and wiring diagrams.
- Routine test reports and type test data.
- Special test requirements specified by the project.
- Scope of Factory Acceptance Test (FAT).
- Accessories list and monitoring & control configuration.
- Export packaging, transportation, and delivery conditions.
- Warranty scope and related documentation.
When comparing different suppliers, ensure that capacity, voltage, losses, temperature rise, and test conditions are comparable, and do not solely compare the total equipment price.
How Easysail Can Assist
Easysail Transformer provides export procurement support for photovoltaic step-up transformers and related power transformers. You can submit your project's single-line diagram, inverter parameters, grid-connection voltage, capacity, and procurement quantity. We can assist in communicating product configuration, accessories, technical documentation, and supply quotations, helping you compare transformer products that meet your project requirements.